Hot Runner Controls
TC-2000 Main Frames Standard 15 Amp. Index
|
|
|
| 1 Zone Main
Frame MF-1 |
2 Zone Main
Frame MF-2 |
 |
 |
| Max. Amperage |
15 Amps |
Total of 20 Amps for system |
| Power |
240 VAC, Single
Phase, 3 Wire (2 AC & 1 Ground), 50-60 Hz. |
| Mold Interface |
Accomplished
through 1 single 5 wire cable construction of 2 thermocouple leads, 2
power leads and 1 ground lead per zone. |
| Vital Feature |
Anti-Arching
circuitry |
| Construction |
Steel frame with
handle; air vent on bottom & side for cooling; top & bottom module
insertion guides; 4 rubber feet; 3 pin male AC input socket installed on
top of main frame; 5 pin female power/thermocouple connector (1Z-FC) with
latch installed on top of main frame and 3 prong input power cord plug
(1Z-PP without input cord) is supplied. NOTE : If a
power/thermocouple cable (PTC-1) is not ordered with main frame, 1 or 2
male cable connector/s (1Z-ME) will be provided. |
| Dimensions & Weight |
9" (H) x
7" (W) x 11.5" (D); Approx. 7 lbs (without modules & cables) |
| Compatibility |
Compatible with
industry standard control modules and main frames |
|
|
| Five Zone Main Frame MF-5-150 |
| Max. Amperage |
15 Amps per zone |
|
| Power |
240 VAC, Single
Phase, 3 Wire (2 AC & 1 Ground), 50-60 Hz. |
| Circuit Breaker |
50 Amps, 3 Pole ** |
| Vital Feature |
Anti-Arching
circuitry |
| Thermocouple |
Type "J" |
| Mold Interface |
Accomplished through dedicated power cord with ground
(PWC-5) and Thermocouple cable (THC-5) |
| Construction |
Heavy duty welded aluminum frame; air vent on bottom & side for cooling; top & bottom module
insertion guides. Thermocouple Connector (FCK-TC, 25 pin, male) &
Power Connector (FCK-PR, 25 pin, female) are mounted on the LHS of the
main frame. Input power cord grip is mounted on RHS of the main frame
(input power cord in not supplied). Completely self contained with no
external components required. PFS-5 Floor Stand can be used to mount the
main frame. It accepts all ITC temperature control modules. |
| Dimensions & Weight |
9" (H) x 20.25" (W) x 11.5" (D); Approx. 15 lbs (without modules & cables) |
| Compatibility |
Compatible with industry standard control
modules and main frames |
Top |
|
|
|
|
Eight Zone Main Frame
MF-8-150
|
Sixteen Zone Main Frame
MF-16-170
|
Sixteen Zone Main Frame
MF-16-250
|
|

|

|

|
| Circuit Breaker |
(1) 50 Amps, 3 Pole ** |
(1) 70 Amps, 3 Pole ** |
(2) 50 Amps, 3 Pole ** |
|
Single 8 Zone main frame construction |
Two 8 Zone Main Frames stacked construction |
Two 8 Zone Main Frames stacked construction |
| Max. Amperage |
15 Amps per zone |
| Power |
240 VAC, Single
Phase, 3 Wire (2 AC & 1 Ground), 50-60 Hz. |
| Vital Feature |
Anti-Arching
circuitry |
| Thermocouple |
Type "J" |
| Mold Interface |
Accomplished through dedicated power cord with ground
(PWC-8) and Thermocouple cable (THC-8) |
| Construction |
Heavy duty welded aluminum frame; air vent on bottom & side for cooling; top & bottom module
insertion guides. Thermocouple Connector (FCK-TC, 25 pin, male) &
Power Connector (FCK-PR, 25 pin, female) are mounted on the LHS of the
main frame. Input power cord grip is mounted on RHS of the main frame
(input power cord in not supplied). Completely self contained with no
external components required. PFS-812 Floor Stand can be used to mount the
main frame. It accepts all ITC temperature control modules. |
| Compatibility |
Compatible with industry standard
control modules and main frames |
| Dimensions & Weight (without modules
& cables) |
9" (H) x 20.25" (W) x 11.5" (D); Approx. 15 lbs |
18" (H) x 20.25" (W) x 11.5" (D); Approx.
32 lbs |
18" (H) x 20.25" (W) x 11.5" (D); Approx.
32 lbs |
Top |
|
|
|
Twelve Zone Main Frame
MF-12-150
|
Twenty Four
Zone Main Frame
MF-24-250
|
Thirty Six
Zone Main Frame
MF-36-350
|
|

|

|

|
| Circuit Breaker |
(1) 50 Amps, 3 Pole ** |
(2) 50 Amps, 3 Pole ** |
(3) 50 Amps, 3 Pole ** |
| Modular Construction |
Single 12 Zone main frame construction |
Two 12 Zone Main Frames stacked construction.
Rigidly connected & pre-wired. |
Three 12 Zone Main Frames stacked construction.
Rigidly connected & pre-wired. |
| Dimensions & Weight (without modules
& cables) |
9" (H) x 28.25" (W) x 11.5" (D); Approx.
20 lbs |
18" (H) x 28.25" (W) x 11.5" (D); Approx.
42 lbs |
27" (H) x 28.25" (W) x 11.5" (D); Approx.
66 lbs |
| Max. Amperage |
15 Amps per zone |
| Power |
240 VAC, Single
Phase, 3 Wire (2 AC & 1 Ground), 50-60 Hz. |
| Vital Feature |
Anti-Arching
circuitry |
| Thermocouple |
Type "J" |
| Mold Interface |
Accomplished through dedicated power cord with ground
(PWC-12) and Thermocouple cable (THC-12) |
| Construction |
Heavy duty welded aluminum frame; air vent on bottom & side for cooling; top & bottom module
insertion guides. Thermocouple Connector (FCK-TC, 25 pin, male) &
Power Connector (FCK-PR, 25 pin, female) are mounted on the LHS of the
main frame. Input power cord grip is mounted on RHS of the main frame
(input power cord in not supplied). Completely self contained with no
external components required. PFS-812 Floor Stand can be used to mount the
main frame. It accepts all ITC temperature control modules. |
| Compatibility |
Compatible with industry standard
control modules and main frames |
Top |
|
| |
| Twenty Zone Mainframe MF-20-170
|
Twenty Zone Mainframe MF-20-250
|
| Circuit Breaker |
(1) 70 Amps, 3 Pole ** |
(2) 50 Amps, 3 Pole ** |
| Modular Construction |
8 Zone Main Frame is mounted on 12 Zone Main Frame.
Rigidly connected & pre-wired. |
8 Zone Main Frame is mounted on 12 Zone Main Frame.
Rigidly connected & pre-wired. |
| Dimensions & Weight (without modules
& cables) |
18" (H) x 28.25" (W) x 11.5" (D); Approx.
37 lbs |
| Max. Amperage |
15 Amps per zone |
| Power |
240 VAC, Single
Phase, 3 Wire (2 AC & 1 Ground), 50-60 Hz. |
| Vital Feature |
Anti-Arching
circuitry |
| Thermocouple |
Type "J" |
| Mold Interface |
Accomplished through dedicated power cord with ground
(PWC-12 & PWC-8) and Thermocouple cable (THC-12 & THC-8) |
| Construction |
Heavy duty welded aluminum frame; air vent on bottom & side for cooling; top & bottom module
insertion guides. Thermocouple Connector (FCK-TC, 25 pin, male) &
Power Connector (FCK-PR, 25 pin, female) are mounted on the LHS of the
main frame. Input power cord grip is mounted on RHS of the main frame
(input power cord in not supplied). Completely self contained with no
external components required. PFS-812 Floor Stand can be used to mount the
main frame. It accepts all ITC temperature control modules. |
| Compatibility |
Compatible with industry standard
control modules and main frames |
Top |
|
|
|